Aviom MH10f Uživatelská příručka

Procházejte online nebo si stáhněte Uživatelská příručka pro Hudební nástroje Aviom MH10f. Aviom MH10f User guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 144
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User Guide

P/N 9310 1013 0001F rev. 1.00© 2008 Aviom, Inc.User Guide6416mMic Input ModuleMic Control SurfaceRemote Control InterfaceRCI

Strany 2

xA-Net Slot Display. . . . . . . . . . . . . . . . . . . 76Select a Slot . . . . . . . . .

Strany 3 - WARNING!

88BUILDING A PRO64 NETWORKExample 5: One input module and two output modules in Manual Mode B AInputB AOutputB AOutputThe inp

Strany 4 - Important Safety Instructions

89 BUILDING A PRO64 NETWORKExample 6: Two input modules and two output modules, 16x16B AInputB AOutputB AOutputB AInp

Strany 5 - Warranty Information

90BUILDING A PRO64 NETWORKExample 7: Audio from the stage is output at the front-of-house mixing console; audio from the FOH console is output on the

Strany 6 - Aviom, Inc. Limited Warranty

91 BUILDING A PRO64 NETWORKDigital Copies in Manual ModeCreating a digital split in Manual Mode follows most of the rules defined for Auto Mode splits

Strany 7 - ABLE OF CONTENTS

92BUILDING A PRO64 NETWORKinput module at front of house. Unlike Auto Mode, however, this input module needs to be set to send audio data to its A-Net

Strany 8

93 BUILDING A PRO64 NETWORKExample 9: A digital copy of the stage signals B AInputB AOutputB AOutputB AInputSTAGEFRON

Strany 9

94VDC CONFIGURATIONVDC Configuration Pro64’s Virtual Data Cables provide an easy way to distribute control signals throughout a network, greatly expan

Strany 10

95 VDC CONFIGURATIONVDC SLOTRS-232MIDI InMIDI OutGPIO InGPIO OutASSIGNPORTWhen a rear-panel VDC port has been assigned to a VDC Slot, its In Use LED

Strany 11

96VDC CONFIGURATIONAssigning a VDC SlotThe act of assigning a VDC Slot maps one of the rear-panel hardware VDC I/O ports to a Virtual Data Cable. To a

Strany 12

97 ADVANCED FUNCTIONSAdvanced FunctionsThe available advanced functions for the 6416m Input Module are listed in the table below. No Advanced Function

Strany 13 - Features

xiDimensions - RCI . . . . . . . . . . . . . . . . . . . 113MCS Specifications. . . . . . . . .

Strany 14 - The EtherCon Connector

98ADVANCED FUNCTIONSany front-panel button other than a channel activation button after the Function button will also cancel the Function request. Cl

Strany 15 - Rack Mounting

99 ADVANCED FUNCTIONSTo lock the network, press the FUNCTION button on the Control Master module. The Function button and Enter/Cancel LEDs will flash

Strany 16 - Cleaning

100ADVANCED FUNCTIONSSample Alignment All digital networks that allow daisy-chained connectivity need to compensate for sub-millisecond latency build-

Strany 17 - About A-Net

101 ADVANCED FUNCTIONSTo get sample alignment info, press the FUNCTION button, followed by the CHANNEL 11 A CTIVE button. Press ENTER; the A-Net Slot

Strany 18 - A-Net Ports

102ADVANCED FUNCTIONSnetwork is power cycled. When the network is reconfigured or when the sample rate is changed, a new value should be calculated us

Strany 19 - BOUT A-NET

103 ADVANCED FUNCTIONSManaged Mode is deactivated.tt Edit Lock is set to off. t Password protect is off.The system t password value for the module

Strany 20 - Changing Values

104FIRMWARE UPDATE Firmware UpdatePro64 modules can be updated in the field using a PC and the Pro64 Update Tool application. Modules can be updated o

Strany 21 - DIP Switches

105 FIRMWARE UPDATE device. To enable firmware updates on the module, press FUNCTION, followed by the CHANNEL 15 ACTIVE button. The Enter/Cancel LED a

Strany 22 - NTER button

106FIRMWARE UPDATE came with the update firmware. During the update, the module’s sixteen red, yellow, and green channel meter LEDs will flash in sequ

Strany 23 - A-Net Slot

107 Specifications6416m Block DiagramGain0–55dBProgrammableRS-232Level meterMIDI InMIDI OutGPIODB25 Female (x2)Alternate Input/Passive SplitsXLR Balan

Strany 25 - A-Net Slot Display

108Specifications6416m SpecificationsChannels 16 inputs Mic- or line-levelXLR Inputs Pin 1: Shield; Pin 2: Hot; Pin 3: ColdPassive Splitter/ Alternat

Strany 26 - ANCEL button

109 SpecificationsA-Net 2 EtherCon RJ45 connectorsA-Net Cable Length 400 feet (120 meters) Cat-5e between devices Latency Analog input to analog outpu

Strany 27 - A-Net Slot Example

110SpecificationsDimensions - 6416m

Strany 29 - Network Modes

112SpecificationsRCI SpecificationsController Port Front panel; EtherCon RJ45, Accepts MCSHeadphone Monitor 1/4-inch TRS, mono, with level controlMo

Strany 30

113 SpecificationsDimensions - RCI

Strany 32 - Control Master Functions

115 SpecificationsMCS SpecificationsController Port EtherCon RJ45, Connects to RCIChannel Level 64 bicolor LEDsHigh Resolution Meter 10-segment, -4

Strany 33 - Changing Settings

116SpecificationsDimensions - MCS

Strany 34 - GPIO Out

117 Specifications

Strany 35 - Network Sample Rate

1 ABOUT YOUR PRO64 PRODUCTWelcomeThank you for purchasing the 6416m Mic Input Module, RCI Remote Control Interface and MCS Mic Control Surface. This U

Strany 36 - Mute Mute

118SpecificationsMounting the MCS The underside of the MCS has two keyhole openings that allow the MCS to be attached to another surface using only tw

Strany 37 - Managed Mode

119 SPECIFICATIONSGPIO Specifications The following table lists the specifications for the General Purpose Input/Output (GPIO) terminal blocks found

Strany 38 - Password Protection

120SPECIFICATIONSGPIO PlugsPlugs used with the GPIO terminal blocks have the following specifications. Pitch 3.81 mmNumber of positions 8Type of conne

Strany 39 - ONTROL MASTER

121 SpecificationsDB25 Audio ConnectionsAviom analog input and output modules with DB25 multi-pin connectors are wired to the analog pinout that has b

Strany 40 - 6416m Front Panel Components

122SpecificationsUsing DB25 JacksThe DB25 panel-mount connectors on Aviom products have #4-40 UNC threads. Be sure to get DB25 breakout cables with th

Strany 41

123 SpecificationsRS-232 Cables and Pinout Using an RS-232 device with Pro64 devices requires a female-to-female DB9 null modem cable (also referred

Strany 42

124SpecificationsWiring a Crossover CableThe following table can be used to create a crossover cable: Crossover CablePin # Pin # 1 and 6423324 1 and

Strany 43 - Input Module

125 IndexINDEXSymbols4-pin XLR 7124VDC supply 50, 71+48V Button 74+48V Phantom Power 816416dio 436416i 566416m DC Requirements 246416m Specica

Strany 44 - Mic Input Module

126IndexAuto Mode 6, 17, 19, 39, 45, 67Active channels 46Available A-Net Slots 12, 17Merger Hub 86Auto Mode Connections 84Available A-Net Slots

Strany 45

127 IndexClock 20DIP switch 20, 33DIP switch 10 36Password 99Reset 103Sample Alignment Lock 101Control Master DIP Switch 63Control Master Error

Strany 46 - A-NET SLOT

2ABOUT YOUR PRO64 PRODUCTRear-panel XLR line-level output for monitoring tselected mic preamp channel Pad switch for XLR line-level outputtBackup DC

Strany 47 - A-Net Transmit

128IndexFunction 03 98Function 09 99Function 10 99Function 11 101, 102Function 12 101Function 13 101Function 14 102Function 15 104Function 16

Strany 48 - Sample Rate

129 IndexMManaged button 25, 26, 30, 42Managed Mode 25, 42, 98Enter/exit 42Manual LED 35Manual Mode 6, 17, 19, 35, 39, 45, 46, 67, 87Active chann

Strany 49 - NTER button. To exit without

130IndexConnecting, Managed Mode 26Firmware update 104Peak Hold Button 74 , 82Personal MixerA-16II, A-16R 7Phantom Power 50MCS 81Phase 53Phase

Strany 50

131 IndexSample Alignment 100, 101, 102Sample Rate 5, 12, 18, 19, 23, 28, 36, 38, 40, 45, 102, 108A-Net Slots 23Available A-Net Slots 12Changing

Strany 51 - A-Net Slot Configuration

132Indexdeactivate 60DIP switches 20In Use 59In Use LED 95Query Functions 43Reset 103RS-232 pinout 123VDC Conguration 30, 94VDC inputs 96VDC

Strany 52

3 MAINTAINING YOUR PRO64 PRODUCTAC PowerAlways plug the unit into a properly grounded (earthed) outlet. Always use the AC line cord that was shipped w

Strany 53 - A-Net LED

4MAINTAINING YOUR PRO64 PRODUCTTransporting the 6416m in a RackThe 6416m Mic Input Module has attachment points for rear support hardware built into t

Strany 54 - Edit Lock Button

5 ABOUT A-NETAbout A-Net Aviom’s A-Net® is the only networking technology conceived, designed, and optimized for managing and distributing audio usin

Strany 55 - Query Functions (Get Info)

6ABOUT A-NETClocking The Pro64 network offers the most flexible clocking and synchronization options in the industry. Pro64 devices support three rang

Strany 56 - Control Group

7 ABOUT A-NETMode network, two 64-channel streams are available on the cable and in each module. The configuration of the cables and ports has an impa

Strany 57 - Channel Activation Button

IITrademarks Aviom and the Aviom logo are trademarks of Aviom, Inc. A-Net and the A-Net logo are trademarks of Aviom, Inc. Pro16, Pro64, and Virtual

Strany 58 - Stereo Link Button

8PRO64 INTERFACE CONVENTIONSPro64 Interface ConventionsMany Pro64 Series products have similar user interface components, including buttons, LEDs, and

Strany 59 - UTE button once to activate

9 PRO64 INTERFACE CONVENTIONSThe buttons with up/down indicator arrows are used for the inc/dec functions. Buttons of this type will be referred to as

Strany 60 - Phase Button

10PRO64 USER INTERFACEPro64 User InterfaceThis section outlines some basic concepts of operation for Pro64 products. Pro64 I/O devices have some comm

Strany 61 - Gain (dB)

11 PRO64 USER INTERFACEEdit LockManagedCONTROLMASTERENTERCANCELVDC SLOTRS-232MIDI InMIDI OutGPIO InGPIO OutASSIGNPORTThe LED between the Enter and Can

Strany 62 - +48V Phantom Power Button

12PRO64 USER INTERFACEconsoles, mic preamps, DSP processors, and DAW software. We use the word ‘’channel’’ when referring to the physical audio input

Strany 63

13 PRO64 USER INTERFACEThe current sample rate will also affect the display of available A-Net Slot ranges. Slot ranges will always have the same maxi

Strany 64 - FRONT PANEL

14PRO64 USER INTERFACETo select an A-Net Slot range, use the inc/dec buttons below the display. Press one of the buttons until the desired base Slot r

Strany 65 - Mic Preamp Presets

15 PRO64 USER INTERFACEA-Net Slot ExampleThe following example shows the power of the Pro64 network and the A-Net Slots concept. The range of A-Net Sl

Strany 66 - Preset Rules

16PRO64 USER INTERFACEBy activating a group of channels on each of the four input modules, a total of sixteen inputs are used (indicated by reverse te

Strany 67 - Backup DC Power

17 PRO64 USER INTERFACENetwork ModesA Pro64 audio network can be set to operate in one of two modes, Auto or Manual. The network mode can be selected

Strany 68 - Balanced Mic/Line Inputs

IIINO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLYTo reduce the risk of fire or electrical shock, do not expose

Strany 69 - DB25 Audio Thru/Alternate In

18PRO64 USER INTERFACEnew data. This means that, while no more than 128 channels can be in the network at a particular location, there is no practical

Strany 70 - DATA CABLES

19 CONTROL MASTERPro64 Network ConceptsConfiguring a Pro64 network involves a few simple steps. This section details some of the global settings and n

Strany 71 - Configuring a VDC

20CONTROL MASTERSetting Control Master StatusSetting the 6416m to be the Control Master is done using the DIP switches found on the rear panel. The Co

Strany 72 - GPIO INPUT

21 CONTROL MASTERfunctions or settings. During the enumeration process, all connected A-Net modules will flash their A-Net LEDs, indicating that a req

Strany 73 - RS-232 Port

22CONTROL MASTEREdit LockManagedCONTROLMASTERENTERCANCELVDC SLOTRS-232MIDI InMIDI OutGPIO InGPIO OutASSIGNPORTThe Enter/Cancel LED will ash when the

Strany 74 - RS-232 Baud Rates

23 CONTROL MASTERExternal clock sources on the 6416dio Digital I/O Module can include: t Word Clock - via the dedicated BNC Word Clock jack t AES3 (

Strany 75 - Control Master DIP Switch

24CONTROL MASTERSample RateLinkMute MuteØPress the selection button to cycle through the available sample rates. The current sample rate for the netwo

Strany 76 - HEADPHONES

25 CONTROL MASTERA-NET SLOTPort APort BAutoA-NETTRANSMITManualCLOCKMASTERSample RateFUNCTIONThe selection button in the A-Net Transmit section of the

Strany 77 - CONTROLLER

26CONTROL MASTEREdit LockManagedCONTROLMASTERENTERCANCELVDC SLOTRS-232MIDI InMIDI OutGPIO InGPIO OutASSIGNPORTManaged Mode allows the network to be co

Strany 78 - RCI Rear Panel Components

27 CONTROL MASTERmodule, as well as the In Use LED for all active VDC Slots in the network. This query behavior is similar to the behavior of an indiv

Strany 79 - Network Mode Selection

IVImportant Safety InstructionsRead these instructions.1. Keep these instructions2. Heed all warnings.3. Follow all instructions.4. Do not use this ap

Strany 80

286416M COMPONENTS6416m Front Panel ComponentsA-NET SLOTEditPort APort BAutoA-NETTRANSMITManualCLOCKMASTERCONTROLSample Rate12345LinkLinkMuteEditMuteE

Strany 81 - Group 4Group 3

29 6416M COMPONENTS6416m Front Panel ComponentsLevel Meter LEDs1. 2. Stereo Link ButtonMute Button3. Phase, Low Cut, Pad, and +48V LEDs4. Edit Button

Strany 82

306416M COMPONENTS6416m Front Panel Components1. A-Net LED 2. Control Master LED3. VDC Slot and Port Configuration4. Managed Mode Button 5. Edit L

Strany 83 - FUSE: VAC-FAL

31 6416M COMPONENTS1. XLR mic/line inputsPower On/Off Switch2. 3. IEC Power Inlet4. Fuse HolderBackup DC Power Inlet5. Control Master DIP Switch (#1

Strany 84 - +dBu LINELEVEL OUTPUT BAL

326416M COMPONENTS6416m Rear Panel Components1. DB25 Audio Thru/Alternate In, x22. Virtual Data Cable Ports3. GPIO Configuration DIP Switches4. GP

Strany 85 - MCS Components

33 NETWORK SETTINGS6416m Network SettingsThere are a few basic concepts that need to be understood when setting up a Pro64 network. Some of the functi

Strany 86

34NETWORK SETTINGSA-Net Slot Range Configuration The A-Net Slot section of the interface is used to set the range of A-Net Slots that the 6416m will u

Strany 87 - Inc/Dec Selection Buttons

35 NETWORK SETTINGSNetwork Mode The LEDs in the A-Net Transmit section show information about the current network mode, which can be set to Auto Mode

Strany 88

36NETWORK SETTINGSPort APort BAutoA-NETTRANSMITManualA-Net data is set to transmit out of Port B in Manual Mode in this example. Changing the A-Net T

Strany 89 - Save and Recall Buttons

37 NETWORK SETTINGSSample Rate A-Net Slots Available44.1/48kHz 64 88.2/96kHz 32176.4/192k Hz 16 In an all-analog network, the sample rate can be set a

Strany 90 - Gain Display

VWarranty InformationPlease record the following information for future reference:Your Authorized Aviom Dealer:Name: Address: Phone: Serial Numbe

Strany 91 - Gain Control

38NETWORK SETTINGSCLOCKMASTERSample RatePressing the selection button will cycle through the available sample rates. 96kHz is shown in the example.

Strany 92 - Pad Button

39 6416M FRONT PANEL6416m Front Panel FeaturesThis section describes the features and functions of all front-panel components of the 6416m Mic Input M

Strany 93 - High Resolution Meter

406416M FRONT PANELthrough the various choices. Clock Master Every Pro64 network will have one Clock Master. The module designated as Control Master w

Strany 94 - Controller Connector

41 6416M FRONT PANELVDC Slot and Port ConfigurationThere are 14 Virtual Data Cable Slots available to transport user control data throughout the Pro64

Strany 95 - Connecting Pro64 Modules

426416M FRONT PANELbench configured (it is not part of an active network), the A-Net LED will be off during the firmware update. (Check the Aviom webs

Strany 96 - Auto Mode Connections

43 6416M FRONT PANELThe Edit Lock button, along with the Enter button,t can be used to unlock the unit. t Gain switches on I/O modules such as the

Strany 97 - B A

446416M FRONT PANELTo Exit the query function, press EDIT LOCK followed by ENTER to return to normal operation. Control Group The Control Group functi

Strany 98

45 6416M FRONT PANEL6416m Channel Strip Functions The features of the 6416m mic preamp channels are described in detail in this section. Most of these

Strany 99 - Manual Mode Connections

466416M FRONT PANELChannel Activation RulesIt is not necessary to press the ENTER button to activate or deactivate a channel. Each Pro64 module rememb

Strany 100 - A PRO64 NETWORK

47 6416M FRONT PANELTo link a pair of channels, both channels must be active on the network first; the Active button located below the Edit button mus

Strany 101

VIAviom, Inc. Limited WarrantyAviom, Inc. warrants this product against defects in materials and workmanship for a period of one year from the date of

Strany 102

486416M FRONT PANELEdit Button The Edit button gives the user access to each channel’s settings for Phase, Low Cut filter, Pad, +48V phantom power, an

Strany 103 - Digital Copies in Manual Mode

49 6416M FRONT PANELLow Cut Button The Low Cut button applies a bass rolloff filter centered at 85Hz to the selected channel. Use this to eliminate lo

Strany 104

506416M FRONT PANELWhen the 24dB pad is in use, the Pad LED in the selected channel strip will be lit.Mic pre Presets save the Pad state for each chan

Strany 105

51 6416M FRONT PANELChannel Gain Each input channel on the 6416m has an individual gain setting controlled by the Gain knob. Press EDIT to select a ch

Strany 106 - VDC Configuration

526416M FRONT PANELUse the selection button to cycle through the selections, Groups 1-4 and Off. Only active mic channels in the currently selected Co

Strany 107 - VDC In Use LED

53 6416M FRONT PANELMic Preamp Presets Each 6416m Mic Input Module has the ability to save 16 mic preamp Presets. Parameters that can be saved per cha

Strany 108 - NTER to deactivate the

546416M FRONT PANEL NOTE: To save a mic preamp Preset from the MCS, remember that the 6416m needs to be set to the same Control Group as is currentl

Strany 109 - UNCTION button; its button

55 6416M REAR PANEL FEATURES6416m Rear Panel Features All 6416m rear-panel features and functions are described in this section. AC Power Pro64 module

Strany 110 - Password Lock

566416M REAR PANEL FEATURES6416m DC Requirements Like most electronic devices, the 6416m will draw more than its rated current for a very brief period

Strany 111 - Set a New Password

57 6416M REAR PANEL FEATURESDB25 Audio Thru/Alternate In Two female DB25 multipin connectors are provided for audio throughput on the 6416m, creating

Strany 112 - Sample Alignment

viiTABLE OF CONTENTSWarranty Information . . . . . . . . . . . . . . . . . . . . vWelcome . . . . .

Strany 113 - FUNCTIONS

58VIRTUAL DATA CABLES ChannelDB25 Pin NumberHot Cold Ground12412252102311321922472085186196417571531681142 No Connect 13 13 12 11

Strany 114 - Restore Factory Defaults

59 VIRTUAL DATA CABLES Virtual Data Cables Three types of Virtual Data Cable (VDC) ports are available on the rear panel of the 6416m Input Module. Fo

Strany 115

60VIRTUAL DATA CABLES To output control data that originates at the 6416m from another Pro64 module elsewhere in the network, select the same numbered

Strany 116 - Firmware Update

61 VIRTUAL DATA CABLES MIDI In, MIDI Out Two MIDI (Musical Instrument Digital Interface) ports, In and Out, are provided on the 6416m. Each is capable

Strany 117 - UNCTION, followed

62VIRTUAL DATA CABLES RS-232 Configuration DIP Switches RS-232 communication is configured using the first eight switches in the DIP switch block. Swi

Strany 118 - UPDATE

63 VIRTUAL DATA CABLES SwitchBaud Rate 1 2341200 off off off off2400 off off off on4800 off off on off7200 off off on on9600 off on off off14400 of

Strany 119 - 6416m Block Diagram

64RCI FRONT/REAR PANELRCI Front Panel ComponentsHEADPHONES1. Headphone Input JackHeadphone 2. Monitor Volume Control 3. Network Mode Selection A-

Strany 120 - 6416m Specifications

65 RCI FRONT/REAR PANELRCI Front Panel Components1. A-Net LED 2. Controller Input for MCSCONTROLLER

Strany 121 - Specifications

66RCI FRONT/REAR PANEL1. Power On/Off Switch2. IEC Power Inlet3. Fuse Holder4. Backup DC Power InletBalanced 5. Line-Level Monitor Output, XLR6.

Strany 122 - Dimensions - 6416m

67 RCI FRONT/REAR PANELRCI Front Panel Features The RCI provides a network access point for remote control of the 6416m. Any number of RCI Remote Cont

Strany 123

viiiChanging the Network Mode . . . . . . . . . . 25Managed Mode . . . . . . . . . . . . . . . . .

Strany 124 - RCI Specifications

68RCI FRONT/REAR PANELPort APort BAuto and Manual Mode LEDs and Port selection options A-Net SlotThe A-Net Slot display shows the network Slot that is

Strany 125 - Dimensions - RCI

69 RCI FRONT/REAR PANELSync Indicator The dot in the Slot Selection display is used to indicate that Slot selection is being controlled from the MCS M

Strany 126

70RCI FRONT/REAR PANELLED will flash while a request to enter the network is sent to and then processed by the device designated as Control Master. On

Strany 127 - MCS Specifications

71 RCI FRONT/REAR PANELAC Power Pro64 modules use switching power supplies that can operate at 100-240V and from 50-60 Hz, meaning that they can be us

Strany 128 - Dimensions - MCS

72RCI FRONT/REAR PANELPAD +dBu LINELEVEL OUTPUT BALPIN  HOT The RCI outputs the currently selected Slot as a +4dBu mono line-level audio signal.

Strany 129

73 MCS FEATURESMCS ComponentsBicolor LED 1. Channel Level Meters 2. Numeric Keypad 3. Inc/Dec and Up/Down Selection Buttons4. A-Net Slot Display

Strany 130 - Mounting the MCS

74MCS FEATURESMCS Components1. Phase Button 2. Low Cut Button 3. Mute Button 4. Pad Button 5. +48V Phantom Power Button 6. High Resolution Meter 7

Strany 131 - GPIO Specifications

75 MCS FEATURESMCS Features The MCS is used to edit 6416m mic preamp settings and save/recall presets remotely. A single MCS connected to an RCI can b

Strany 132 - MIDI/GPIO Cable Lengths

76MCS FEATUREScurrent network sample rate). Follow the selection rules above; press ENTER or simply wait for the Slot to be automatically selected. Pr

Strany 133 - Wiring an Analog DB25 Cable

77 MCS FEATURESPress t ENTER to immediately display the selected channel/Slot number, or Do nothing; after a short pause, the interface will tautoma

Strany 134 - Using DB25 Jacks

ixSave a Preset . . . . . . . . . . . . . . . . . . . . . 53Recall a Preset . . . . . . .

Strany 135 - RS-232 Connections

78MCS FEATURESTo use the Save and Recall functions from the MCS, any 6416m Mic Input Modules that you want to control need to be set to the same Contr

Strany 136 - Wiring a Crossover Cable

79 MCS FEATURESdisplay will be blank for non-controllable Slots. No ntrolThe current gain setting is displayed for any active mic preamp channel when

Strany 137

80MCS FEATURESNo ntrolThe channel strip, high resolution meter, and gain settingsLow Cut Button The Low Cut button applies a bass rolloff filter cente

Strany 138

81 MCS FEATURESMic pre Presets save the Pad state for each channel. +48V Phantom Power Button Phantom power for devices such as condenser mics is avai

Strany 139

82MCS FEATURESThe high resolution meter and Peak Hold buttonPeak Hold Button When on, the Peak Hold function will show and hold the highest level (inc

Strany 140

83 BUILDING A PRO64 NETWORKBuilding a Pro64 Network Configuring a Pro64 network involves connecting input and output modules with Cat-5e cables, setti

Strany 141

84BUILDING A PRO64 NETWORKBasic RoutingTo output the mic/line audio inputs connected to the 6416m, the module must be connected to another Pro64 devic

Strany 142

85 BUILDING A PRO64 NETWORKof Slots within the network. Example 2: Port B connected to Port A B AInputB AOutputIn this diagram, note

Strany 143

86BUILDING A PRO64 NETWORKExample 3: One input module and three digital copies in Auto Mode B AInputB AOutputB AOutputB

Strany 144

87 BUILDING A PRO64 NETWORKExample 4: One input module and three output modules connected using an MH10/MH10f in Auto Mode B AInputB

Komentáře k této Příručce

Žádné komentáře